Search results for "Relative Biological Effectiveness"

showing 10 items of 10 documents

Differential Superiority of Heavy Charged-Particle Irradiation to X-Rays: Studies on Biological Effectiveness and Side Effect Mechanisms in Multicell…

2016

This review is focused on the radiobiology of carbon ions compared to X-rays using multicellular models of tumors and normal mucosa. The first part summarizes basic radiobiological effects, as observed in cancer cells. The second, more clinically oriented part of the review, deals with radiation-induced cell migration and mucositis. Multicellular spheroids from V79 hamster cells were irradiated with X-rays or carbon ions under ambient or restricted oxygen supply conditions. Reliable oxygen enhancement ratios could be derived to be 2.9, 2.8, and 1.4 for irradiation with photons, (12)C(+6) in the plateau region, and (12)C(+6) in the Bragg peak, respectively. Similarly, a relative biological e…

0301 basic medicinePathologymedicine.medical_specialtyCancer Researchcell migrationMotilityReviewBiologylcsh:RC254-28203 medical and health sciences0302 clinical medicinerelative biological effectivenessRadioresistancemedicineRelative biological effectivenessorganotypic tumor and mucosa culturesparticle irradiationCell migrationOxygen enhancement ratio (OER)lcsh:Neoplasms. Tumors. Oncology. Including cancer and carcinogensrelative biological effectiveness (RBE)030104 developmental biologymucositisOncologyradiobiologyCell cultureApoptosis030220 oncology & carcinogenesisCancer cellOxygen enhancement ratioBiophysicsoxygen enhancement ratioFrontiers in Oncology
researchProduct

Response of Chinese Hamster V79 Multicellular Spheroids Exposed to High-Energy Carbon Ions

2004

Chinese hamster V79-379A spheroids 200 +/- 30 microm (+/- SD) in diameter were irradiated in agitated medium in different oxygen atmospheres with (1) 227 MeV/nucleon (12)C(+6) ions (plateau region) to model tissue in the entrance channel during therapy, (2) carbon ions in the extended Bragg peak modeling tissue in the target volume, or (3) X rays as a reference modality. Cell survival curves were similar for modes (1) and (3), indicating the absence of a contact effect and the presence of a pronounced oxygen effect with oxygen enhancement ratios (OERs) of 2.8 and 2.9, respectively. In contrast, the oxygen effect was substantially smaller in mode (2) with an OER of 1.4. Under normal or restr…

Cell SurvivalBiophysicsAnalytical chemistrychemistry.chemical_elementApoptosisBragg peakRadiation DosageOxygenChinese hamsterCell LineIonCricetulusCricetinaeRelative biological effectivenessAnimalsRadiology Nuclear Medicine and imagingCarbon RadioisotopesIrradiationRadiationbiologyX-RaysCell CycleSpheroidDose-Response Relationship Radiationbiology.organism_classificationOxygenchemistryAtomic physicsCarbonCell DivisionRelative Biological EffectivenessRadiation Research
researchProduct

Characterization of PTW-31015 PinPoint ionization chambers in photon and proton beams

2018

The increased use of complex forms of radiotherapy using small-field photon and proton beams has invoked a growing interest in the use of micro-ionization chambers. In this study, 48 PTW-TM31015 PinPoint-type micro-ionization chambers that are used in the commissioning and patient specific QA of a proton pencil beam scanning (PBS) delivery system have been characterized in proton and high-energy photon beams. In both beam modalities, the entire set of PinPoint chambers was characterized by imaging them, by evaluating their stability using check source measurements, by experimentally determining the ion recombination, polarity effect and by cross calibrating them in terms of absorbed dose to…

PhotonProton030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticscross-calibrationIonizationProton TherapyCalibrationHumansDosimetryRadiology Nuclear Medicine and imagingCobalt RadioisotopesRadiometryPencil-beam scanningpolarity effectPinPoint ionization chamberPhysicsPhotonsion recombinationRadiological and Ultrasound Technologybusiness.industryphoton030220 oncology & carcinogenesisCalibrationPhysics::Accelerator PhysicsProtonLaser beam qualityProtonsbusinessRelative Biological EffectivenessBeam (structure)Physics in Medicine & Biology
researchProduct

Phantom size in brachytherapy source dosimetric studies

2004

An important point to consider in a brachytherapy dosimetry study is the phantom size involved in calculations or experimental measurements. As pointed out by Williamson [Med. Phys. 18, 776-786 (1991)] this topic has a relevant influence on final dosimetric results. Presently, one-dimensional (1-D) algorithms and newly-developed 3-D correction algorithms are based on physics data that are obtained under full scatter conditions, i.e., assumed infinite phantom size. One can then assume that reference dose distributions in source dosimetry for photon brachytherapy should use an unbounded phantom size rather than phantom-like dimensions. Our aim in this paper is to study the effect of phantom s…

Photonmedicine.medical_treatmentBrachytherapyMonte Carlo methodBrachytherapyModels BiologicalSensitivity and SpecificityImaging phantomRelative biological effectivenessmedicineHumansScattering RadiationDosimetryComputer SimulationPoint (geometry)RadiometryRadioisotopesPhysicsPhantoms Imagingbusiness.industryRadiotherapy Planning Computer-AssistedReproducibility of ResultsRadiotherapy DosageGeneral MedicineRadiusComputational physicsOrgan SpecificityBody BurdenRadiopharmaceuticalsNuclear medicinebusinessMonte Carlo MethodAlgorithmsRelative Biological EffectivenessMedical Physics
researchProduct

Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams.

2020

The beam quality correction factor k Q for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed on the widely used NE-2571 ionization chamber have been used to benchmark the results. The Monte Carlo code PENELOPE/penEasy was used to calculate the absorbed dose to a point in water and the absorbed dose to the active air volume of the chambers for photon beams in the range 4 to 24 MV. Of the nine ionization chambers analysed, only five are included in the current version of…

PhysicsPhotonsPhotonRadiological and Ultrasound TechnologyMonte Carlo methodUncertaintyWater030218 nuclear medicine & medical imagingNuclear physics03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisIonizationAbsorbed doseIonization chamberRelative biological effectivenessDosimetryRadiology Nuclear Medicine and imagingLaser beam qualityRadiometryMonte Carlo MethodRelative Biological EffectivenessPhysics in medicine and biology
researchProduct

Technical note: Monte Carlo derivation of TG-43 dosimetric parameters for radiation therapy resources and 3M Cs-137 sources

2005

In clinical brachytherapy dosimetry, a detailed dose rate distribution of the radioactive source in water is needed in order to plan for quality treatment. Two Cs-137 sources are considered in this study; the Radiation Therapy Resources 67-800 source (Radiation Therapy Resources Inc., Valencia, CA) and the 3M model 6500/6D6C source. A complete dosimetric dataset for both sources has been obtained by means of the Monte Carlo GEANT4 code. Dose rate distributions are presented in two different ways; following the TG43 formalism and in a 2D rectangular dose rate table. This 2D dose rate table is helpful for the TPS quality control and is fully consistent with the TG43 dose calculation formalism…

Physicsmedicine.medical_specialtyPhotonbusiness.industrymedicine.medical_treatmentRadioactive sourceBrachytherapyMonte Carlo methodGeneral MedicineComputational physicsRadiation therapymedicineRelative biological effectivenessDosimetryMedical physicsbusinessQuality assuranceMedical Physics
researchProduct

Determination of consensus kQ values for megavoltage photon beams for the update of IAEA TRS-398

2020

The IAEA is currently coordinating a multi-year project to update the TRS-398 Code of Practice for the dosimetry of external beam radiotherapy based on standards of absorbed dose to water. One major aspect of the project is the determination of new beam quality correction factors, kQ, for megavoltage photon beams consistent with developments in radiotherapy dosimetry and technology since the publication of TRS-398 in 2000. Specifically, all values must be based on, or consistent with, the key data of ICRU Report 90. Data sets obtained from Monte Carlo (MC) calculations by advanced users and measurements at primary standards laboratories have been compiled for 23 cylindrical ionization chamb…

TRS-398INMRImedicine.medical_treatmentMonte Carlo method030218 nuclear medicine & medical imagingNuclear physics03 medical and health sciences0302 clinical medicinemedicineRelative biological effectivenessDosimetryRadiology Nuclear Medicine and imagingExternal beam radiotherapyMonte CarloPhysicsMV photon beamsRadiological and Ultrasound Technologydosimetryionization chambersmetrologymetrologia030220 oncology & carcinogenesisAbsorbed doseIonization chamberPhoton beamsbeam quality correction factorsLaser beam quality
researchProduct

Combined TL and 10B-alanine ESR dosimetry for BNCT

2004

The dosimetric technique described in this paper is based on electron spin resonance (ESR) detectors using an alanine-boric compound acid enriched with 1 0 B, and beryllium oxide thermoluminescent (TL) detectors; with this combined dosimetry, it is possible to discriminate the doses due to thermal neutrons and gamma radiation in a mixed field. Irradiations were carried out inside the thermal column of a TRIGA MARK II water-pool-type research nuclear reactor, also used for Boron Neutron Capture therapy (BNCT) applications, with thermal neutron fluence from 10 9 to 10 1 4 n t h cm - 2 . The ESR dosemeters using the alanine-boron compound indicated ESR signals about 30-fold stronger than those…

inorganic chemicalsMaterials scienceBeryllium oxidechemistry.chemical_elementBoron Neutron Capture TherapyRadiationRisk AssessmentSensitivity and SpecificityThermoluminescencelaw.inventiondosimeters electron paramagnetic resonancespin resonancechemistry.chemical_compoundRadiation ProtectionIsotopeslawHumansDosimetryRadiology Nuclear Medicine and imagingBoronElectron paramagnetic resonanceBoronNeutronsRadiationRadiological and Ultrasound Technologybusiness.industryRadiotherapy Planning Computer-AssistedRadiochemistryElectron Spin Resonance SpectroscopyPublic Health Environmental and Occupational HealthReproducibility of ResultsRadiotherapy DosageGeneral MedicineSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Neutron temperatureSystems IntegrationNeutron capturechemistryGamma RaysBody BurdenThermoluminescent DosimetryNuclear medicinebusinessRelative Biological EffectivenessRadiation Protection Dosimetry
researchProduct

Dose calculation in biological samples in a mixed neutron-gamma field at the TRIGA reactor of the University of Mainz

2010

To establish Boron Neutron Capture Therapy (BNCT) for non-resectable liver metastases and for in vitro experiments at the TRIGA Mark II reactor at the University of Mainz, Germany, it is necessary to have a reliable dose monitoring system. The in vitro experiments are used to determine the relative biological effectiveness (RBE) of liver and cancer cells in our mixed neutron and gamma fi eld. We work with alanine detectors in combination with Monte Carlo simulations, where we can measure and characterize the dose. To verify our calculations we perform neutron fl ux measurements using gold foil activation and pin-diodes . Material and methods . When L- α -alanine is irradiated with ionizing …

inorganic chemicalsPhysics::Instrumentation and DetectorsQuantitative Biology::Tissues and OrgansPhysics::Medical PhysicsBoron Neutron Capture TherapyValidation Studies as TopicModels BiologicalIonizing radiationTRIGAHospitals UniversityNuclear ReactorsCell Line TumorGermanyRelative biological effectivenessMedicineDosimetryHumansRadiology Nuclear Medicine and imagingNeutronNeutronsbusiness.industryRadiotherapy Planning Computer-AssistedRadiochemistryLiver NeoplasmsRadiotherapy DosageHematologyGeneral MedicineHep G2 CellsNeutron temperatureNeutron captureOncologyGamma RaysAbsorbed dosebusinessNuclear medicineColorectal Neoplasms
researchProduct

EPR DOSIMETRY IN A MIXED NEUTRON AND GAMMA RADIATION FIELD

2004

Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the 'international intercomparison of criticality dosimetry techniques' at the SILENE reactor held in Valduc in June 2002, France. These three materials were irradiated in neutron and gamma-ray fields of various relative intensities and spectral distributions in order to evaluate their neutron sensitivity. The neutron response was found to be around 10% for tooth enamel, 45% for mannose and between 40 and 90% for alanine pellets according their type. According to the IAEA recommendations on the early estimate of criticality accident a…

inorganic chemicalsSafety ManagementMaterials scienceQuality Assurance Health CareRadiation DosageRisk AssessmentSensitivity and Specificitylaw.inventionRadiation Protectionstomatognathic systemlawNuclear ReactorsRisk FactorsmedicineDosimetryHumansRadiology Nuclear Medicine and imagingNeutronIrradiationElectron paramagnetic resonanceSpectroscopyRadiometryNeutronsObserver VariationRadiationRadiological and Ultrasound Technologybusiness.industryRadiochemistryPublic Health Environmental and Occupational HealthElectron Spin Resonance SpectroscopyReproducibility of ResultsGeneral MedicineReference StandardsTooth enamelEPR DOSIMETRY MIXED NEUTRON AND GAMMA RADIATION FIELDstomatognathic diseasesmedicine.anatomical_structureCriticalityGamma RaysAbsorbed doseBody BurdenFranceNuclear medicinebusinessRadioactive Hazard ReleaseRelative Biological Effectiveness
researchProduct